Bombing/Gross/Fine Leak Test System

MSX-7000 series

This system can control bombing conditions (Helium charge), gross leak tests, and fine leak tests. Industry’s first model which is compatible with 1.0 x 0.8 size. Conveyance accuracy is improved through position correction which uses image processing.

Basic Specifications

Target Test Size

Compatible with 2 types 1.0×0.8mm, 1.2×1.0mm
Thickness: 0.3~0.5mm (Requirements over 0.5mm are subuject to inquiry.)

Process Capacity

12ch 1.0s/part(Bombing 60min)

Judgment Level(Pa・m³/s)

Gross Leak: 8.5×10⁻⁸~Large leak(equivalent standard leak)
Fine Leak: 1×10⁻⁹~(He)

Power Source/Applied Current

AC200V±10% three-phase 50/60Hz / 2kVA

Pneumatic Pressure Source

0.5 MPa or above

Helium/Nitrogen Source

Adjust the external cylinder of the equipment to 0.6 MPa.
Purity at over 99.99%

External Dimensions (mm)

W1800×D1400×H1800(excluded signal tower)

Download materials

Please feel free to contact us for any inquiry.

Please feel free to contact us for any inquiry.

Table-top type air leak tester for gross leak test.

Fully-automatic high-precision machine optimal for reducing testing times.
12ch Spec.

Fully-automatic high-precision machine optimal for reducing testing times.

Fully-automatic Bombing/Gross/Fine Leak Test System

This air leak test system for gross leak testing is fully automatic, including fully-automatic gross leak determination.

A device of leak test system suited for evaluation testing (during device development, etc.)

Bench Top type air leak tester for gross leak test.

Hermeticity inspection system for relatively large device products up to 10×10 mm size or smaller.
This single unit is a combined airtightness inspection unit that

Media Sosial

Copyright © 2010 | PT. Fukuda Technology